Seasonal solar production

What your panels make in each month of the year next to what you use, and how every roof direction and tilt compares.

Data: PVGIS 5.3 (EU Joint Research Centre), Enemalta tariffs, REWS feed-in tariff table. Retrieved 22 November 2026. Runs in your browser; nothing is stored or sent. Methodology.

The panels
Island
PVGIS point used: Malta 35.90 N 14.51 E, Gozo 36.04 N 14.24 E.
Direction the panels face
°
Compass bearing: 0 = north, 90 = east, 180 = south, 270 = west.
°
0 = flat, 90 = vertical. For Malta about 31° is best for yearly output.
kWp
An example size.
%
Cabling, inverter, dust and ageing. PVGIS default 14%. How it scales.
%
Water tanks, parapets or a taller building next door. PVGIS does not see these. Your estimate.
Your use

Give your yearly use, or type all twelve months from your bills to see the seasons properly.

kWh
Your bills show it. 3,500 kWh is the regulator's reference household, not a measured average (REWS 2026).
Enter twelve monthly readings instead
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh

Results update as you type. Reset puts every field back to the values this page opened with.

Solar output and use by month

Bars: what the panels make each month (PVGIS). Line: your use, spread by days per month unless you entered your own readings.

  • Solar output
  • Your use
Show the figures as a table

Every direction and tilt

Yearly output per kWp from the PVGIS grid for your island and losses. Darker is more. The ring marks your roof; click a cell to try that orientation.

—— kWh per kWp a year

Assumptions and sources

Every default above can be changed. This is where each one comes from. The full formulas, retrieval dates and limits are on Methodology and sources.

Monthly output sourced
PVGIS 5.3 monthly averages over 2005-2023, interpolated between grid points; worst month error in our tests 3.1% (steep north-facing roof in winter). PVGIS
Monthly use assumption
Spread by the number of days in each month unless you enter twelve readings. No Maltese monthly household profile is published.
Heatmap sourced
Raw PVGIS grid, 15 tilts by 25 directions, scaled by your system and shading loss.
Best orientation sourced
PVGIS optimum for each point: Malta 31° due south, Gozo 32° facing 3° west of south.

Estimates only. These figures come from a model: PVGIS long-term solar data, today's published tariffs and the assumptions listed. Real output depends on your roof, shading, equipment and weather, and the rules can change. Get written quotes, and confirm grants and the feed-in tariff with REWS before you commit.