Components & Sizing
How big a system do you need, and what should go into it? A practical, Malta-specific guide to sizing, panels, inverters, batteries, roof mounting and the safety-critical balance of system.
Last updated: 22 November 2026
Getting the components right is where a Maltese solar system is won or lost. The panels are the easy part; sizing sensibly for the local yield, choosing an inverter that suits how you use power, and — above all — mounting an array that will survive a gregale are what separate a system that pays for itself from one that disappoints or, in the worst case, ends up in a neighbour's yard.
Sizing: start from your Enemalta bill
Sizing a domestic array is refreshingly simple once you know your annual consumption. Read your yearly usage in kWh straight off your Enemalta bills (add up a full year to smooth out summer air-conditioning), then divide by the local yield to get the array you need in kWp:
Array size (kWp) ≈ annual consumption (kWh) ÷ ~1,550
That 1,550 is a deliberately conservative planning figure. Malta's specific yield is genuinely high — PVGIS models around 1,650–1,680 kWh per kWp per year at an optimal tilt — but sizing on the lower number leaves headroom for panel degradation, heat losses, dust and the odd cloudy spell, so you are never disappointed. Always model your own roof in PVGIS before committing; it accounts for your exact orientation, tilt and any shading.
| Annual use (from Enemalta bill) | Array size (÷ 1,550) | ~450 W panels |
|---|---|---|
| 3,000 kWh | ~1.9 kWp | 4–5 |
| 4,500 kWh | ~2.9 kWp | 6–7 |
| 6,000 kWh | ~3.9 kWp | 8–9 |
| 8,000 kWh | ~5.2 kWp | 11–12 |
Most Maltese domestic systems land in the 3–6 kWp range, and the vast majority of installations nationally are 11 kWp or under. There is little point building much bigger than your consumption on a grid-tied system.
Don't massively oversize an on-grid system
On a grid-connected system your surplus is exported and paid at the feed-in tariff, which is lower than the price you pay to import. Every kWh you generate and can't use yourself earns you less than the one it displaces, so a heavily oversized array has a poor return. Size to your own consumption; if you want to store surplus for the evening rather than sell it cheap, that is exactly what a battery is for — and you can size the array a little larger to feed it. See government incentives for how the tariff and battery grants interact.
Panels: monocrystalline, and keep them cool
The mainstream choice is a monocrystalline PERC or TOPCon module in the 400–500 W band — roughly the ~450 W figure the sizing table assumes. Two things matter more in Malta than the glossy efficiency number on the datasheet:
- A low temperature coefficient. Panel output falls as the cells heat up, and Maltese rooftops get very hot for months on end. A module with a gentler temperature coefficient loses less of its rated power on a 40°C afternoon — exactly when you are running the air-conditioning.
- An air gap under the panels. Mount with a clear ventilation gap so air can move behind the modules and shed heat, rather than sitting flush against a baking roof.
Whatever you pick must carry genuine CE marking and IEC 61215 / 61730 certification to pass grid approval. Our solar panel types guide compares the technologies in detail.

Inverters: string, hybrid or micro?
The inverter turns the panels' DC into usable AC and is the brain of the system. There are three broad choices:
| Inverter type | Best for | Trade-off |
|---|---|---|
| String | Simple, unshaded roofs on the tightest budget | Cheapest, but no battery or backup on its own; a shaded panel drags down the whole string |
| Hybrid (recommended) | Most Maltese homes — adds a battery and outage backup | Costs more than plain string, but matches the battery grant rules when a call is open and future-proofs storage |
| Microinverters | Shaded, complex or multi-orientation roofs | Per-panel optimisation, but the most expensive option with many units on the roof |
For most households we lean towards a hybrid inverter: it lets you add storage now or later, keeps power on during a cut (a plain grid-tie inverter shuts down in an outage by design), and lines up with the battery-and-inverter track of the REWS scheme. Whatever you choose, every grid-tied inverter in Malta must meet the EN 50549-1 grid code, including anti-islanding protection so it stops feeding a dead line. Our inverter guide covers the grid-code requirements in full.
Batteries: LiFePO4, sized to the evening
Storage is now dominated by LiFePO4 (lithium iron phosphate) chemistry — safer and longer-lived than older lithium types. Size the battery to the load you want to carry through the evening and overnight, once the sun is off the panels; for a typical home that is roughly 5–10 kWh of usable capacity. Two practical points:
- 48 V low-voltage vs high-voltage. Low-voltage 48 V packs are common and flexible for domestic sizes; high-voltage stacks suit larger systems and pair with specific inverters. Match the battery to your chosen inverter, not the other way around.
- The BMS must talk to the inverter. Every pack needs a battery management system, and it must communicate with the inverter over CAN or RS485 — and the battery must be on that inverter's approved compatibility list. A battery the inverter can't properly manage is a safety and warranty problem, not a bargain.
Remember lithium cells are dangerous goods to ship, so for an imported system the battery is usually the one component worth buying locally. See battery storage for chemistry, sizing and the grant detail.
Mounting for Maltese roofs
This is where Malta really differs from a mainland install, and where an under-engineered system becomes dangerous. The typical Maltese roof is a flat concrete or limestone slab already shared with water tanks, a solar water heater, washrooms and the odd stairwell. You are fitting the array around all of that.
Ballasted (non-penetrating) — the norm
- Weighted tilt frames sit on the slab, held down by concrete blocks or trays — no drilling.
- Protects the waterproof membrane; nothing to leak.
- The catch: the ballast must be engineered for wind uplift, not guessed.
Penetrating (fixed)
- Brackets bolted through into the structure — a very secure fixing.
- Every penetration must be properly flashed and sealed, or it will leak.
- Used where ballast weight is a problem or the fixing needs to be positive.
Aim for a tilt of around 30° (up to about 35°) facing due south for the best year-round yield. Then leave space to live with the array: enough row spacing that one row doesn't shade the next in the low winter sun, maintenance walkways to reach panels and tanks, and clearance from the water tanks and heater. And confirm the roof structure actually carries the full load — panels, frame, ballast and wind uplift combined; if there is any doubt, get a perit to check it.
Wind loading is the critical Maltese factor
Malta's winds are fierce — the north-westerly majjistral and, worse, the north-easterly gregale (grigal) can be violent. A tilted panel is a sail: the wind tries to lift the array off the roof. Under-ballasted arrays have been torn off Maltese roofs. Ballast and anchoring must be engineered to Eurocode EN 1991-1-4 and its Malta National Annex for your specific roof height and exposure — get the wind-load calculation from the racking manufacturer or a perit. This is not a step to eyeball.
Balance of system
The "balance of system" is everything between the panels and a safe, code-compliant connection. On an exposed Maltese rooftop these parts are not optional extras — they are the difference between a certifiable installation and a fire risk.
| Component | Why it matters |
|---|---|
| DC-rated isolator | Must be rated for the string's full open-circuit voltage (Voc) so the DC side can be broken safely |
| AC isolator | Isolates the inverter from the grid connection |
| Surge protection (SPD) | On both DC and AC sides — exposed rooftops take lightning and switching surges |
| String fusing | Protects each string against fault and back-feed current |
| DC cable | Correctly sized, UV-rated and mechanically secured for years of rooftop sun |
| MC4 connectors | Genuine, matched brand-to-brand — mismatched connectors are a known arc and fire cause |
| Earthing & bonding | Frames and array properly earthed and bonded |
| 30 mA RCD | Residual-current protection required by the installation regulations |
The DC side is live in daylight — and the AC side is professional territory
Solar panels generate voltage whenever light hits them; you cannot switch them off at the panel, which makes DC-rated isolators, matched MC4 connectors and correctly sized cable a genuine arc-and-fire safety matter, not a formality. The AC-side balance of system — the consumer-unit tie-in, RCD, earthing and commissioning — is part of the certified installation and must be done and signed off by a warranted professional before Enemalta will energise the system. See DIY on-grid solar for exactly where the homeowner's role ends and the certifier's begins.
Choose components for how you actually use power and for the roof you actually have, and never let price alone decide the parts that keep the system safe. Size honestly from your bill, pick a low-temperature-coefficient panel with an air gap, favour a hybrid inverter if you want storage and backup, insist the battery's BMS is matched to that inverter, and treat the mounting's wind-load calculation as the single most important number on the whole job. Get those right and the rest — certification, connection and the grant — follows cleanly.