Battery sizing and break-even
How much more of your own solar a battery lets you use, what that is worth against the feed-in tariff, and how long it takes to pay for itself.
Bigger is not always better
Extra benefit in year 1 for battery sizes from 0 to 20 kWh, with your other settings. The curve flattens once the battery can hold the whole evening's use; the circle marks your size.
- Extra benefit per year
Show the figures as a table
Assumptions and sources
Every default above can be changed. This is where each one comes from. The full formulas, retrieval dates and limits are on Methodology and sources.
- Battery model sourced
- Each month's average day, hour by hour: surplus solar charges the battery, the evening deficit drains it, repeated until the charge at midnight settles.
- Round-trip efficiency 91.8% sourced
- Powerwall 3 datasheet: 89% solar-to-battery-to-grid against 97% solar-to-grid. Tesla datasheet
- Depth of discharge 100% sourced
- For usable capacity as quoted on BYD and Huawei datasheets.
- Capacity loss not sourced: your input
- No independent field rate found. 0 unless you enter one.
- Battery price not sourced: your input
- Your quote. No default.
- Load shape assumption
- Assumed, not measured. Try the evening shape to see the best case for a battery.
- Value of a stored kWh sourced
- The tariff band your use falls out of, minus what that kWh would have earned as export.
- Battery grant sourced
- 2026 terms (75%, €6,000, €600/kWh), closed. What-if only.
Estimates only. These figures come from a model: PVGIS long-term solar data, today's published tariffs and the assumptions listed. Real output depends on your roof, shading, equipment and weather, and the rules can change. Get written quotes, and confirm grants and the feed-in tariff with REWS before you commit.